INA219: Variation is large for current more than 300mA

$
0
0

Part Number:INA219

Hi TI Support Team,

We are using INA219 in our design.

  • Python Modules to talk to INA219 via FTDI chip
  • Max Current that can flow through : 3A
  • Shunt Resistor : 10mOhm

Calibration Procedure:

  • Using Electronic Load, applied the load at the INA219 and calibrated.
  • INA219 measured valued is cross checked with the Current Probe

The deviation is large. over 200mA when the load changes in real time. Kindly please advise how this can solved.