INA228-Q1: Current Sense Amplifier Comparison and Error Tool

$
0
0
Part Number: INA228-Q1
Other Parts Discussed in Thread: INA236, INA228, INA238

Tool/software:

Hello Team,

I was calculating current measurement error using your Current_Sense_Amplifier_Comparison_and_Error_Tool and got the below results.

However, I have few queries as follows:

1. Is ENOB value considered in the tool to calculate error in lower range ?

2. What output sample period is considered during the ADCRANGE & ENOB selection if applicable ?

3. Why there is no change in error value if I use INA236 full scale ADCRANGE 1 (±20.48-mV) or ADCRANGE 0 (±81.92-mV). Both selection showing same error under same condition.

4. Why aren't INA238 & INA228 having option to select different ADCRANGE ? Are the results same ?

4. Is external common-mode filter will reduce the error or was it considered to calculate Ibias ?

Regards,

Tamal Samanta

Hardware Engineering Team Lead

OÜ Skeleton Technologies
8th Floor, Alma Tomingas house, Sepise 7
11415 Tallinn, Estonia

www.skeletontech.com